2017年9月4日星期一

Reducer use precautions

1, under normal circumstances, for long continuous work of the reducer, according to run 5000 hours or once a year to replace the new oil, long-term use of the reducer, before re-operation should also replace the new oil VF Worm Gearbox should be added with the original grade Of the oil, not with different grades of oil mixed with the same grades and different viscosity of the oil allowed to use. In the case of
2, the oil to wait for the coal mill gearbox to cool down after the risk of burning so far, but should remain warm, because the complete cooling, the oil viscosity increases, oiling difficulties. Note: To cut off the drive power, to prevent inadvertently power! In the case of
3, the work, when the oil temperature rise above 80 ℃ or oil tank temperature exceeds 100 ℃ and produce abnormal noise and other phenomena should stop using, check the reasons, must be troubleshooting, the replacement of lubricants before they can continue to run The In the case of
4, the user should have a reasonable use of maintenance rules and regulations, the operation of the reducer and the problems found in the test should be carefully recorded, the above provisions should be strictly enforced.